Ross Controls 15407-1 &2 SERIES W66 User Manual
How to order

6
© 2012,
ROSS
CONTROLS
®
.
All Rights Reserved.
Series W66 (15407-2)
Size 00 (18mm), Double Solenoid (5/2)
Series W66 (15407-2)
Size 0 (26mm), Double Solenoid (5/3)
Open Center
Series W66 (15407-1)
Size 00 (18mm), Single Solenoid (5/2)
Function*
4-Way
2-Position
Remote Pilot
56
Solenoid Pilot
76
4-Way
3-Position
Remote Pilot
57
Solenoid Pilot
77
Dual
3-Way
2-Position
Normally Open
70
Normally Closed
75
NC / NO
NC - 14 End
78
W66
76
A
0
4
01
W
Options*
4-W
ay 2-Position
Single
Plug-In (15407-2)
Non-Locking Overrides
Internal Pilot -
01
External Pilot -
51
Locking Overrides
Internal Pilot -
11
External Pilot -
21
Drop Cord (15407-1)
Non-Locking Overrides
Internal Pilot -
61
External Pilot -
81
Locking Overrides
Internal Pilot -
71
External Pilot -
91
Double
Plug-In (15407-2)
Non-Locking Overrides
Internal Pilot -
07
External Pilot -
57
Locking Overrides
Internal Pilot -
17
External Pilot -
27
Drop Cord (15407-1)
Non-Locking Overrides
Internal Pilot -
67
External Pilot -
87
Locking Overrides
Internal Pilot -
77
External Pilot -
97
4-W
ay 3-Position
Closed
Center
Plug-In (15407-2)
Non-Locking Overrides
Internal Pilot -
01
External Pilot -
51
Locking Overrides
Internal Pilot -
11
External Pilot -
21
Drop Cord (15407-1)
Non-Locking Overrides
Internal Pilot -
61
External Pilot -
81
Locking Overrides
Internal Pilot -
71
External Pilot -
91
Power
Center
Plug-In (15407-2)
Non-Locking Overrides
Internal Pilot -
03
External Pilot -
53
Locking Overrides
Internal Pilot -
13
External Pilot -
23
Drop Cord (15407-1)
Non-Locking Overrides
Internal Pilot -
63
External Pilot -
83
Locking Overrides
Internal Pilot -
73
External Pilot -
93
Open
Center
Plug-In (15407-2)
Non-Locking Overrides
Internal Pilot -
07
External Pilot -
57
Locking Overrides
Internal Pilot -
17
External Pilot -
27
Drop Cord (15407-1)
Non-Locking Overrides
Internal Pilot -
67
External Pilot -
87
Locking Overrides
Internal Pilot -
77
External Pilot -
97
Dual 3-W
ay
2-Position
Plug-In (15407-2)
Non-Locking Overrides
Internal Pilot -
07
Locking Overrides
Internal Pilot -
17
Drop Cord (15407-1)
Non-Locking Overrides
Internal Pilot -
67
Locking Overrides
Internal Pilot -
77
Basic Size
Size 00 (18mm)
0
Size 0 (26mm)
1
Voltage
24 VDC
W
120 VAC
Z
* Be sure to choose Options from the correct list. For example,
if a Function of 4-Way 2-Position is chosen, then only choose
Options from the section listed for that function. See the light
gray-shaded columns of the Function and Options lists.
ISO Size 00 & 0 Valves Series W66
HOW TO ORDER
(Choose your options (in red) to configure your valve model number.)