beautypg.com

3 automatic mode, Figure 8-11: smart fan setting – pwm mode – IEI Integration IMBA-Q454 v1.01 User Manual

Page 185

background image

IMBA-Q454-R10 User Manual

Page 185

Figure 8-11: Smart Fan Setting – PWM Mode

8.4.3.3 Automatic Mode

In the Automatic Mode, the user can set the temperature that decides the fan activity. The

following value can be set (

978H

Figure 8-12):

ƒ Fan Start (°C): the fan starts when the temperature reaches the set value

ƒ Fan Off (°C): the fan turns off when the temperature reaches the set value

ƒ Full Speed (°C): the fan runs at full speed when the temperature reaches the

set value

ƒ Start PWM Value (0~127): the initial PWM value when the fan starts

ƒ Slope (PWM Value (add/°C): the PWM value added per degree Celsius (°C)

of temperature increase when the fan start running

To set the value, double click the number and enter a new value. Click apply or ok when

finish.