B
Connection Panels and LED Indicators
Trimble Placer GPS 455DR
Figure 110 Trimble Placer connector panel
Table 4
Trimble Placer connector panel descriptions (see
Figure 110
)
Connector Name
Cable Part Number
Opposite End of Cable Connects To
GPS Antenna
E6450-80002
GPS antenna
Radio
8120-8650
GPS RS-232 port of the E645xx receiver
or
Serial port of the computer (this option requires a Dual Serial Port
PCMCIA card)
MDT/RTCM
If you have a Differential GPS, connect its data cable to this port.
This port is also used for sensor calibration. When calibrating,
remove the cable from the Radio port, then connect it to the
MDT/RTCM port. When calibration is complete, reconnect the
cable to the Radio port.
Heading Sensor
Trimble p/n 30513
Heading Sensor lead: Connect to the heading sensor
ODO 0 Red lead: Connect to the odometer pulse signal
ODO 0 Black lead: Connect to ground.
Digital I/O
(none)
(not used)
Power
5182-1290
4-to-1 lighter socket adapter