beautypg.com

6 browsing to a networked analyzer – Teledyne LeCroy PETracer ML Analyzer and Exerciser User Manual User Manual

Page 38

background image

Chapter 3: Installation

PETracer ML User Manual

30

Teledyne LeCroy

3.6 Browsing to a Networked Analyzer

For the PETracer ML and the PETrainer ML, you can browse to a networked analyzer.

To browse to a networked Analyzer:

Step 1 From the menu, select Setup > Analyzer Network. The Analyzer

Network dialog box opens. Locally connected Analyzers (connected via
USB) display in the list. The list may also show host machines and
Analyzers identified in previous sessions.

Step 2 If the desired host machine and Analyzer are not present in the list, click

Add. The Add Analyzer dialog box opens.

Step 3 Browse to the host machine that has the Analyzer(s), then click Select.

The selected host machine and its Analyzer appear in the Analyzer
Network browse dialog.


Note: The Analyzer must be turned on before it appears in the list.

Step 4 Remove host machines and Analyzers you do not intend to use in the

current recording session by selecting them from the list and clicking
Remove.

The PETracer software establishes a connection to the selected Analyzer.