Step 5.
Reconnect cable W108 to A5J4 and disconnect cable W121 at
A5J5.
Step 6.
Using the oscilloscope, verify the presence of a 10 MHz TTL
signal at the end of cable W121.
G
If present, replace the A5 PCB.
G
If not present, go to step 7.
Step 7.
Reconnect cable W121 to A5J5 and disconnect it at A4J7.
Step 8.
Using the oscilloscope, verify the presence of a 10 MHz TTL
signal at A4J7.
G
If present, replace the cable W121.
G
If not present, go to step 9.
Step 9.
Reconnect cable W121 to A4J7 and disconnect cable W105 at
A4J6.
Step 10. Using the oscilloscope, verify the presence of a 10 MHz TTL
signal at the end of cable W105.
G
If present, replace the A4 PCB.
G
If not present, go to step11.
Step 11. Reconnect cable W105 to A4J6 and disconnect it at A3J4.
Step 12. Using the oscilloscope, verify the presence of a 10 MHz TTL
signal at A3J4.
G
If present, replace the cable W105.
G
If not present, replace the A3 PCB.
Table 5-27.