Troubleshooting, Troubleshooting tables – Anritsu 682XXB User Manual
Page 183
682XXB/683XXB MM
5-17
TROUBLESHOOTING
TROUBLESHOOTING
TABLES
Step 4.
Connect a 562 Scalar Network Analyzer to the 682XXB/
683XXB as follows:
a.
Connect the 682XXB/683XXB
AUX I/O
to the 562
AUX
I/O
.
b.
Connect the 562
DEDICATED GPIB
to the 682XXB/
w683XXB
IEEE-488 GPIB
.
c.
Connect the RF Detector to the 562 Channel A Input.
Step 5.
Set up the 562 Scalar Network Analyzer as follows:
a.
Press SYSTEM MENU display.
b.
From System Menu display, select RESET.
c.
Press CHANNEL 2 DISPLAY: OFF.
d.
Press CHANNEL 1 DISPLAY: ON.
e.
Press CHANNEL 1 Menu key.
f.
From the Channel 1 Menu display, select POWER.
Step 6.
Using the scalar network analyzer, measure the RF output
at J4 of the switched filter assembly. The amplitude of the
RF signal should be >+18 dBm throughout the full sweep.
G
If the amplitude of the RF signal is correct, replace the
SQM.
G
If there is no RF signal or if the amplitude of the RF sig-
nal is low, replace the switched filter assembly.
Table 5-4.
Malfunctions Not Displaying an Error Message (6 of 6)