Troubleshooting, Troubleshooting tables, Power supply tests – Anritsu 682XXB User Manual
Page 185
682XXB/683XXB MM
5-19
TROUBLESHOOTING
TROUBLESHOOTING
TABLES
Power Supply Tests
WARNING
Voltages hazardous to life are present throughout the power
supply circuits, even when the front panel
LINE
switch is in
the
STANDBY
postion. When performing maintenance, use
utmost care to avoid electrical shock.
Error 105 Power Supply Voltage(s) out of Regulation.
Description: The out of regulation circuit, located on the A15 Regula-
tor PCB, monitors all of the regulated power supply outputs. This error
message indicates that one of more of the voltages from the power sup-
ply, with the exception of the 5 volt supply, is out of regulation. If the
5 volt supply is faulty, the 682XXB/683XXB will not operate.
Step 1.
Measure the regulated voltages at the test points shown in
Table 5-7.
G
If incorrect for a supply, go to the referenced step.
G
If incorrect for several supplies, go to step 2.
G
If all voltages are correct, go to step 3.
Table 5-6.
Error Messages 105 and 106 (1 of 10)
Regulated
Voltage
Measurement
Point
Reference
Point
Value
Refer
to Step
+15VG
A15 TP3
A15 TP1
+15V
±
0.75V
4
–15VG
A15 TP9
A15 TP1
–15V
±
0.75V
4
+15VA
A15 TP2
A15 TP1
+15
±
0.75V
5
–15VA
A15 TP7
A15 TP1
–15V
±
0.75V
5
+15VLP
A15 TP12
A15 TP1
+15V
±
0.75V
6
–15VLP
A15 TP13
A15 TP1
–15V
±
0.75V
6
+15VFM
A15 TP8
A15 TP1
+15V
±
0.75V
7
–15VFM
A15 TP11
A15 TP1
–15V
±
0.75V
7
–18VT
A15 TP10
A15 TP1
–18.06V
±
0.36V
8
–43VT
A15 TP15
A15 TP1
–43.1V
±
0.9V
9
+24VH
A15 TP6
A15 TP1
+24.32V
±
0.5V
10
Table 5-7.
Regulated Power Supply Voltages