Troubleshooting, Troubleshooting tables – Anritsu 682XXB User Manual
Page 201
682XXB/683XXB MM
5-35
A11 FM PCB
Error 116 FM Loop Gain Check Failed
Description: The FM loop has failed or the loop gain is out of toler-
ance.
Step 1.
Perform a preliminary calibration. (Refer to chapter 4 for the
calibration procedure.)
Step 2.
Run self-test.
G
If error 116 is not displayed, the problem is cleared.
G
If error 116 is still displayed, go to step 3.
Step 3.
Replace the A11 PCB and run self-test again.
G
If error 116 is not displayed, the problem is cleared.
G
If error 116 is displayed, contact your local
ANRITSU
serv-
ice center for assistance.
Table 5-15.
Error Message 116
TROUBLESHOOTING
TROUBLESHOOTING
TABLES
This manual is related to the following products: