Recommended calibration test equipment – Anritsu 682XXB User Manual
Page 115
682XXB/683XXB MM
4-5
RECOMMENDED
CALIBRATION
TEST EQUIPMENT
INSTRUMENT
CRITICAL
SPECIFICATION
RECOMMENDED
MANUFACTURER/MODEL
PROCEDURE
NUMBER
Scalar Network
Analyzer, with
RF Detector
Frequency Range: 0.01 to 50 GHz
ANRITSU Model 562, with
RF Detector:
560-7K50 (0.01 to 40 GHz)
560-7VA50 (0.01 to 50 GHz)
SC5198 (40 to 60 GHz)
4-8, 4-10
Adapter
K (male) to 2.4 mm (female)
Adapts the Power Sensor, HP 8487A, to
the 682XXB/683XXB RF OUTPUT
connector (
£
40 GHz models)
Hewlett-Packard
Part Number: HP 11904D
4-12
Adapter
Adapts the MP716A4 Power Sensor to
the ML4803A Power Meter
Anritsu MA4002B
4-12
Adapter
WR15 to V (male)
Adapts the MP716A4 Power Sensor to
the 682XXB/683XXB RF OUTPUT
connector (>40 GHz)
ANRITSU, Model 35WR15V
4-12
Attenuator
Frequency Range: DC to 40 GHz
Max Input Power: >+17 dBm
Attenuation: 10 dB
ANRITSU, Model 41KC-10
4-8, 4-9
Attenuator
Frequency Range: DC to 60 GHz
Max Input Power: >+17 dBm
Attenuation: 10 dB
ANRITSU, Model 41V-10
4-8, 4-9
Personal Computer
PC Configuration: IBM AT or compatible
Operating System: Windows 3.1
Accessories: Mouse
Any common source
All procedures
Serial Interface Assy
Provides serial interface between the PC
and the 682XXB/683XXB.
ANRITSU P/N: T1678
All procedures
Tee
Connectors: 50
W
BNC
Any common source
4-12, 4-13,
4-14
Cables
Connectors: 50
W
BNC
Any common source
All procedures
Table 4-1.