IAI America SEL-TG User Manual
Page 96

7. Simple Operation Procedure
78
㽲 Data input for 1st point
Enter a numerical value of 0 and press the return
key. 0.000 is displayed, the axis No. changes to
2, and the cursor moves to the section for the
Y-axis position data.
* The position data can be input up to a 4-digit integral number and three digits to the
right of the decimal. Since the range varies according to t
KHDFWXDWRU¶VPRGHOFKHFNLW
in the catalog etc.
Enter 300 for the Y-axis position data and press
the return key. (* Every time the return key is
pressed, the cursor position moves. With every
press of the
key, the cursor
position moves. When you make an input error,
move the cursor to the location where you have
made the error and overwrite the data.)
The input data can also be returned to X.XXX
with the F3 (Canc) key.
Enter 0 for the Z-axis position data and press the
return key.
Enter 0 for the R-axis position data and press the
return key.
Axis No. at the cursor location