9. Installation
9.2 Installation
Surface
Motor unit types TA4*, TA5*, TA6*, TA7*
x Mount on a strong, rigid structure to prevent vibration.
x Install the main unit only on a machined surface, or other surface that is highly flat, within ±0.05 mm/m.
x Provide adequate space around the device to allow for future maintenance.
x On the motor unit type (TA***) actuator, the side and bottom faces of the base provide reference
surfaces for table's travel.
When it is necessary that the slider or table move in a highly precise fashion, please ensure that the
device is installed at an orientation that is based on the position of these surfaces.
Caution: Because the side and bottom faces of the base provide reference surfaces for table travel as
shown in the above diagram, conduct installation based on the position of this side when
precision is required.
Follow the diagram below when installing the device using the reference surface.
Model
Length of A (mm)
Motor unit type
2 to 4 or less
R0.3 or less
Reference
surface
Reference
surface
Motor unit type