13. Maintenance and Inspection
[How to apply grease for guide rail]
[1]
Turn off the power and pull out the table.
If the lead is too small to move the table, insert a screwdriver, etc., into the cutout groove provided in
the shaft on the rear side and turn. [Refer to 11.4, “How to Move Table by Hand.”]
[2]
Wipe off the grease attached to the V-groove in the guide rail and apply the specified grease.
[3]
Move the table to spread the grease evenly.
Actuator
Table
Table
Guide rail V-groove (2 locations)
Actuator
Guide rail V-groove (2 locations)
Front
Rear
In case the grease got into your eye, immediately go to see the doctor to get an
appropriate care.
After finishing the grease supply work, wash your hands carefully with water and soap
to rinse the grease off.
Caution: