IAI America RCA2-TW4N User Manual
Page 52

44
6. Specifications
Strokes and maximum speed limits (Unit: mm/s)
Model name
Motor type
Lead [mm]
Stroke [mm]
30
TFA3N
TF3N (Option BG)
(Lead screw)
10W
1
50
2
100
4
200
TFA3N
(Ball screw)
10W
1
50
2
100
4
200
TFA4N
TF4N (Option BG)
(Lead screw)
20W
2
100
4
200
6
220
TFA4N
TF4N (Option BG)
(Ball screw)
20W
2
100
4
200
6
270 <220>
(Note) Values in < > are for when mounted vertically.
Note : Do not set a speed or acceleration/deceleration exceeding the applicable rating. Doing so may
result in vibration, failure or shorter life.
Setting the acceleration/deceleration exceeding the applicable rating may also cause creep.