beautypg.com

Gun short circuit current – Ransburg No. 2 Air Motor Atex Approved Unit 80086-XX User Manual

Page 27

background image

27

27

27

27

AH

AH

AH

AH----12

12

12

12----01.03 No. 2 Air Motor Handgun

01.03 No. 2 Air Motor Handgun

01.03 No. 2 Air Motor Handgun

01.03 No. 2 Air Motor Handgun

Gun Short Circuit Current

Gun Short Circuit Current

Gun Short Circuit Current

Gun Short Circuit Current

(SCI) Test

(SCI) Test

(SCI) Test

(SCI) Test

1. Connect wire at contact brush to ground via

1. Connect wire at contact brush to ground via

1. Connect wire at contact brush to ground via

1. Connect wire at contact brush to ground via
microampere meter.

microampere meter.

microampere meter.

microampere meter.

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

All paints and solvents must be purged

All paints and solvents must be purged

All paints and solvents must be purged

All paints and solvents must be purged
from the applicator prior to performing

from the applicator prior to performing

from the applicator prior to performing

from the applicator prior to performing
these tests.

these tests.

these tests.

these tests.

2. Activate applicator slide valve switch to spin

2. Activate applicator slide valve switch to spin

2. Activate applicator slide valve switch to spin

2. Activate applicator slide valve switch to spin

the air motor and initiate high voltage.

the air motor and initiate high voltage.

the air motor and initiate high voltage.

the air motor and initiate high voltage.


3. Read SCI on remote microampere meter:

3. Read SCI on remote microampere meter:

3. Read SCI on remote microampere meter:

3. Read SCI on remote microampere meter:
SCI = 90 to 115 microamperes.

SCI = 90 to 115 microamperes.

SCI = 90 to 115 microamperes.

SCI = 90 to 115 microamperes.

4. If SCI is low or high, see "Paint, High Voltage

4. If SCI is low or high, see "Paint, High Voltage

4. If SCI is low or high, see "Paint, High Voltage

4. If SCI is low or high, see "Paint, High Voltage
& SCI Test Equipment" manual for SCI test pro-

& SCI Test Equipment" manual for SCI test pro-

& SCI Test Equipment" manual for SCI test pro-

& SCI Test Equipment" manual for SCI test pro-
cedure using test probe TE

cedure using test probe TE

cedure using test probe TE

cedure using test probe TE----98

98

98

98----01 Part number

01 Part number

01 Part number

01 Part number

76652.

76652.

76652.

76652.

Item #

Item #

Item #

Item # Description

Description

Description

Description

1

1

1

1

9060 Digital

9060 Digital

9060 Digital

9060 Digital µ

µ

µ

µ

A Meter Readout

A Meter Readout

A Meter Readout

A Meter Readout

2

2

2

2

20988

20988

20988

20988----XX High Voltage Cable

XX High Voltage Cable

XX High Voltage Cable

XX High Voltage Cable

3

3

3

3

20987

20987

20987

20987----XX No. 2 Handgun

XX No. 2 Handgun

XX No. 2 Handgun

XX No. 2 Handgun

4

4

4

4

Earth Ground Connection to Brush

Earth Ground Connection to Brush

Earth Ground Connection to Brush

Earth Ground Connection to Brush

5

5

5

5

Microamp Meter or 76652 to Earth Ground

Microamp Meter or 76652 to Earth Ground

Microamp Meter or 76652 to Earth Ground

Microamp Meter or 76652 to Earth Ground

Figure 16: No. 2 Handgun Short Circuit Current Test Diagram

Figure 16: No. 2 Handgun Short Circuit Current Test Diagram

Figure 16: No. 2 Handgun Short Circuit Current Test Diagram

Figure 16: No. 2 Handgun Short Circuit Current Test Diagram

OPERATION

OPERATION

OPERATION

OPERATION