beautypg.com

Installation, Safeguards safeguards safeguards safeguards, Equipment – Ransburg No. 2 Air Motor Atex Approved Unit 80086-XX User Manual

Page 13

background image

13

13

13

13

AH

AH

AH

AH----12

12

12

12----01.03 No. 2 Air Motor Handgun

01.03 No. 2 Air Motor Handgun

01.03 No. 2 Air Motor Handgun

01.03 No. 2 Air Motor Handgun

INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION

PRE

PRE

PRE

PRE----INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION

REQUIREMENTS

REQUIREMENTS

REQUIREMENTS

REQUIREMENTS

1. Provide approved electrical wiring to the power

1. Provide approved electrical wiring to the power

1. Provide approved electrical wiring to the power

1. Provide approved electrical wiring to the power
supply. The 9060 power supply must be located a

supply. The 9060 power supply must be located a

supply. The 9060 power supply must be located a

supply. The 9060 power supply must be located a
minimum of 6.1m (20’) outside of the hazardous

minimum of 6.1m (20’) outside of the hazardous

minimum of 6.1m (20’) outside of the hazardous

minimum of 6.1m (20’) outside of the hazardous
spray area.

spray area.

spray area.

spray area.

2. Make sure the operating location has adequate

2. Make sure the operating location has adequate

2. Make sure the operating location has adequate

2. Make sure the operating location has adequate
grounding facilities, such as electrical conduit, steel

grounding facilities, such as electrical conduit, steel

grounding facilities, such as electrical conduit, steel

grounding facilities, such as electrical conduit, steel
building columns, metal water pipes, or other earth

building columns, metal water pipes, or other earth

building columns, metal water pipes, or other earth

building columns, metal water pipes, or other earth
grounded objects.

grounded objects.

grounded objects.

grounded objects.

3. Furnish a paint pressure pot with air regulator (or

3. Furnish a paint pressure pot with air regulator (or

3. Furnish a paint pressure pot with air regulator (or

3. Furnish a paint pressure pot with air regulator (or
other accepted pressure system). The regulator

other accepted pressure system). The regulator

other accepted pressure system). The regulator

other accepted pressure system). The regulator
MUST have a reliable control, with a recommended

MUST have a reliable control, with a recommended

MUST have a reliable control, with a recommended

MUST have a reliable control, with a recommended
gauge range of 0

gauge range of 0

gauge range of 0

gauge range of 0----2.1 bar (0

2.1 bar (0

2.1 bar (0

2.1 bar (0----30 psig).

30 psig).

30 psig).

30 psig).


4. Provide proper ventilation. (See "Safety" section of

4. Provide proper ventilation. (See "Safety" section of

4. Provide proper ventilation. (See "Safety" section of

4. Provide proper ventilation. (See "Safety" section of
this manual.)

this manual.)

this manual.)

this manual.)

5. Ensure that the target object to be coated and all

5. Ensure that the target object to be coated and all

5. Ensure that the target object to be coated and all

5. Ensure that the target object to be coated and all
surrounding objects are grounded to a known, earth

surrounding objects are grounded to a known, earth

surrounding objects are grounded to a known, earth

surrounding objects are grounded to a known, earth
ground by a separate ground wire attachment.

ground by a separate ground wire attachment.

ground by a separate ground wire attachment.

ground by a separate ground wire attachment.

SAFEGUARDS

SAFEGUARDS

SAFEGUARDS

SAFEGUARDS


When operating this equipment in the vicinity of

When operating this equipment in the vicinity of

When operating this equipment in the vicinity of

When operating this equipment in the vicinity of
computers, word processors, and/or other elec-

computers, word processors, and/or other elec-

computers, word processors, and/or other elec-

computers, word processors, and/or other elec-
tronic equipment, special care MUST be taken to

tronic equipment, special care MUST be taken to

tronic equipment, special care MUST be taken to

tronic equipment, special care MUST be taken to
ensure that damage does not occur from electrical

ensure that damage does not occur from electrical

ensure that damage does not occur from electrical

ensure that damage does not occur from electrical
energy discharges. (See Ransburg "Safety Litera-

energy discharges. (See Ransburg "Safety Litera-

energy discharges. (See Ransburg "Safety Litera-

energy discharges. (See Ransburg "Safety Litera-
ture" for further information regarding application.)

ture" for further information regarding application.)

ture" for further information regarding application.)

ture" for further information regarding application.)

Do not use the power supply ground wire to ground

Do not use the power supply ground wire to ground

Do not use the power supply ground wire to ground

Do not use the power supply ground wire to ground
target objects. The targets objects must have separate

target objects. The targets objects must have separate

target objects. The targets objects must have separate

target objects. The targets objects must have separate
true earth ground for best efficiency.

true earth ground for best efficiency.

true earth ground for best efficiency.

true earth ground for best efficiency.

C A U T I O N

C A U T I O N

C A U T I O N

C A U T I O N

The following guidelines can be used:

The following guidelines can be used:

The following guidelines can be used:

The following guidelines can be used:

It is highly recommended, whenever pos-

It is highly recommended, whenever pos-

It is highly recommended, whenever pos-

It is highly recommended, whenever pos-
sible, that ALL electronic components or

sible, that ALL electronic components or

sible, that ALL electronic components or

sible, that ALL electronic components or
equipment be removed from the spray

equipment be removed from the spray

equipment be removed from the spray

equipment be removed from the spray
area. This includes computer software

area. This includes computer software

area. This includes computer software

area. This includes computer software
such as tapes, disks, diskettes, etc., lo-

such as tapes, disks, diskettes, etc., lo-

such as tapes, disks, diskettes, etc., lo-

such as tapes, disks, diskettes, etc., lo-
cated inside and/or around the spray ar-

cated inside and/or around the spray ar-

cated inside and/or around the spray ar-

cated inside and/or around the spray ar-
ea.

ea.

ea.

ea.


If the static shielding of a unit is NOT

If the static shielding of a unit is NOT

If the static shielding of a unit is NOT

If the static shielding of a unit is NOT
KNOWN, all electronic components (such

KNOWN, all electronic components (such

KNOWN, all electronic components (such

KNOWN, all electronic components (such
as terminals, screens, and cables) should

as terminals, screens, and cables) should

as terminals, screens, and cables) should

as terminals, screens, and cables) should
be completely wrapped in aluminum foil

be completely wrapped in aluminum foil

be completely wrapped in aluminum foil

be completely wrapped in aluminum foil
and grounded to a true earth ground.

and grounded to a true earth ground.

and grounded to a true earth ground.

and grounded to a true earth ground.


When painting electrical control panels

When painting electrical control panels

When painting electrical control panels

When painting electrical control panels
or consoles, wrap all push

or consoles, wrap all push

or consoles, wrap all push

or consoles, wrap all push----buttons,

buttons,

buttons,

buttons,

switches, meters, or pilot lights with

switches, meters, or pilot lights with

switches, meters, or pilot lights with

switches, meters, or pilot lights with
aluminum foil and ground to the panel

aluminum foil and ground to the panel

aluminum foil and ground to the panel

aluminum foil and ground to the panel
or other earth ground.

or other earth ground.

or other earth ground.

or other earth ground.


EQUIPMENT

EQUIPMENT

EQUIPMENT

EQUIPMENT
INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

NEVER wrap the applicator, associated

NEVER wrap the applicator, associated

NEVER wrap the applicator, associated

NEVER wrap the applicator, associated

valves and tubing, and supporting hard-

valves and tubing, and supporting hard-

valves and tubing, and supporting hard-

valves and tubing, and supporting hard-
ware in plastic to keep it clean. A sur-

ware in plastic to keep it clean. A sur-

ware in plastic to keep it clean. A sur-

ware in plastic to keep it clean. A sur-
face charge may build up on the plastic

face charge may build up on the plastic

face charge may build up on the plastic

face charge may build up on the plastic
surface and discharge to the nearest

surface and discharge to the nearest

surface and discharge to the nearest

surface and discharge to the nearest
grounded object. Efficiency of the appli-

grounded object. Efficiency of the appli-

grounded object. Efficiency of the appli-

grounded object. Efficiency of the appli-
cator will also be reduced and damage

cator will also be reduced and damage

cator will also be reduced and damage

cator will also be reduced and damage
or failure of the applicator's components

or failure of the applicator's components

or failure of the applicator's components

or failure of the applicator's components
may occur.

may occur.

may occur.

may occur.

WRAPPING THESE COMPONENTS IN

WRAPPING THESE COMPONENTS IN

WRAPPING THESE COMPONENTS IN

WRAPPING THESE COMPONENTS IN
PLASTIC WILL VOID WARRANTY.

PLASTIC WILL VOID WARRANTY.

PLASTIC WILL VOID WARRANTY.

PLASTIC WILL VOID WARRANTY.