beautypg.com

Rs-232 connection examples, Igure, 2: rs-232 p – Teledyne 6200A - Sulfides analyzer User Manual

Page 177: Ssignments

background image

TAI Model 6200A SO

2

Analyzer Operator Manual, 02164, Rev. G

Figure 9-2: RS-232 Pin Assignments

9.3.2.1 RS-232 Connection Examples

Example 1

Connecting the 6200A (using supplied cable) to an IBM-PC AT compatible computer (DB-25
external connector, or DB-25 end of DB-9 to DB-25 Adapter).

In this case, the PC is wired as DTE and the analyzer’s jumpers are set as DCE, therefore a null
modem is not needed. The wiring is "straight through" i.e. pin 1 to pin 1, pin 2 to pin 2, etc.
Therefore all you have to do here is adapt the connector on the analyzer cable (male DB-25) to
the DB-25 male on the PC. A female to female DB-25 "gender changer" (cable or adapter) will
complete the connection. Make sure none of the adapters have null modems in them.

9-34