Burkert Type 8056 User Manual
Page 97

- 97 -
RS232_485_ETP_MODBUS_BU_REV02.doc
lblProcessData.Text = lblProcessData.Text &
"Process flags = excitation is too fast for the sensor
connected / temperature error ML211"
& vbCrLf
End
If
If
(afByteReceveBuffer(72)
And
&H2) = &H2
Then
lblProcessData.Text = lblProcessData.Text &
"Process flags = max alarm is active"
& vbCrLf
End
If
If
(afByteReceveBuffer(72)
And
&H4) = &H4
Then
lblProcessData.Text = lblProcessData.Text &
"Process flags = min alarm is active"
& vbCrLf
End
If
If
(afByteReceveBuffer(72)
And
&H8) = &H8
Then
lblProcessData.Text = lblProcessData.Text &
"Process flags = flow rate exceeds the scale range,
overflow"
& vbCrLf
End
If
If
(afByteReceveBuffer(72)
And
&H10) = &H10
Then
lblProcessData.Text = lblProcessData.Text &
"Process flags = too many impulse to emit"
& vbCrLf
End
If
If
(afByteReceveBuffer(72)
And
&H20) = &H20
Then
lblProcessData.Text = lblProcessData.Text &
"Process flags = measurement signal is disturbed or
sensor disconnect"
& vbCrLf
End
If
If
(afByteReceveBuffer(72)
And
&H40) = &H40
Then
lblProcessData.Text = lblProcessData.Text &
"Process flags = empty tube"
& vbCrLf
End
If
If
(afByteReceveBuffer(72)
And
&H80) = &H80
Then
lblProcessData.Text = lblProcessData.Text &
"Process flags = coils not working or sensor disconnect"
& vbCrLf
End
If
If
(afByteReceveBuffer(71)
And
&H1) = &H1
Then
lblProcessData.Text = lblProcessData.Text &
"Process flags = second measurement scale is active"
&
vbCrLf
End
If
If
(afByteReceveBuffer(71)
And
&H2) = &H2
Then
lblProcessData.Text = lblProcessData.Text &
"Process flags = flow rate is lower than the cut-off
threshold"
& vbCrLf
End
If
If
(afByteReceveBuffer(71)
And
&H4) = &H4
Then
lblProcessData.Text = lblProcessData.Text &
"Process flags = flow rate negative"
& vbCrLf
End
If
If
(afByteReceveBuffer(71)
And
&H8) = &H8
Then
lblProcessData.Text = lblProcessData.Text &
"Process flags = new measurement value is available
for the display"
& vbCrLf
End
If
If
(afByteReceveBuffer(71)
And
&H10) = &H10
Then
lblProcessData.Text = lblProcessData.Text &
"Process flags = counter block signal is active"
& vbCrLf