beautypg.com

Burkert Type 8056 User Manual

Page 53

background image

- 53 -

RS232_485_ETP_MODBUS_BU_REV02.doc

Help command: DLMRE=?

1:EXECUTE

if accepted

1:CMD ERR if logging functions not
enabled .
5:ACCESS ERR
if insufficient access

level

Read command: DLUSE?

Status of measure units send if

accepted
1:CMD ERR if RS232 port not enabled
5:ACCESS ERR if insufficient access

level

Set command: DLUSE=

n

0:OK if parameters accepted
1:CMD ERR if RS232 port not enabled

2:PARAM ERR if

n

out of range

5:ACCESS ERR if insufficient access

level

DLUSE (Data Logger measure

Units Send Enable) Enables or
disables the sending of the
measure units of the loggers data

by email using the GPRS terminal.
Not enabling this option makes the

data more compact to send by
wireless communication.

Help command: DLUSE=?

List of

num:description

if accepted

1:CMD ERR if RS232 port not enabled

5:ACCESS ERR if insufficient access
level

Read command: DLTST?

Value of date and time if accepted

1:CMD ERR if logging functions not
enabled

5:ACCESS ERR if insufficient access
level

Set command:

DLTST=

tmstring

Required access level: 2

Value of date and time set

1:CMD ERR if logging functions not
enabled

5:ACCESS ERR if insufficient access
level

DLTST (Data Logger Test Start

Time) Reads or sets the date and
time start value used for the “step

check” test. WARNING: when
setting the date and time,

always check the value
returned because malformed
input string may lead to

incorrect time result.

Help command: DLTST=?

Format of the string to be input

1:CMD ERR if logging functions not
enabled
5:ACCESS ERR if insufficient access

level

Read command: DLTPT?

Value of date and time if accepted

1:CMD ERR if logging functions not
enable
5:ACCESS ERR if insufficient access

level

Set command:
DLTPT=

tmstring

Value of date and time set
1:CMD ERR if logging functions not

enabled
5:ACCESS ERR if insufficient access

level

DLTPT (Data Logger Test stoP

Time) Reads or sets the date and
time stop value used for the “step
check” test. WARNING: when

setting the date and time,
always check the value

returned because malformed
input string may lead to
incorrect time result.

Help command: DLTPT=?

Format of the string to be input
1:CMD ERR if logging functions not

enabled
5:ACCESS ERR if insufficient access

level

DLTTI (Data Logger Test Time
Interval) Reads or sets the time

interval used for the “step check”
test. The time is in minutes.

Read command: DLTTI?

Value of time interval if accepted
1:CMD ERR if logging functions not

enabled
5:ACCESS ERR if insufficient access

level

This manual is related to the following products: