Burkert Type 8056 User Manual
Page 35

- 35 -
RS232_485_ETP_MODBUS_BU_REV02.doc
Set command: VMSGK=
n
0:OK if parameters accepted
1:CMD ERR if weight units not enabled
2:PARAM ERR if
n
out of range
5:ACCESS ERR if insufficient access
level
Help command: VMSGK=?
min <> max
(units)
if accepted
1:CMD ERR if weight units not enabled
5:ACCESS ERR if insufficient access
level
Read command: A1CSY?
Value of analog input 1 measure unit
symbol
1:CMD ERR if analog input 1 not
enabled
5:ACCESS ERR if insufficient access
level
Set command: 1CSY=
string
0:OK if parameters accepted
1:CMD ERR if analog input 1 not
enabled
2:PARAM ERR if
string
length is not 3
chars
5:ACCESS ERR if insufficient access
level
A1CSY (Analog input 1 Custom
SYmbol) Reads or sets the value
representing the custom measure unit
used for the analog input 1. If the
values is to be set, a fixed 3-
characters length string must be
supplied.
Help command: A1CSY=?
3 CHR STRING
if accepted
1:CMD ERR if analog input 1 not
enabled
5:ACCESS ERR if insufficient access
level
Read command: A1MUV?
Value of measure unit if accepted
1:CMD ERR if analog input 1 not
enabled
5:ACCESS ERR if insufficient access
level
Set command: A1MUV=
n
0:OK if parameters accepted
1:CMD ERR if analog input 1 not
enabled
2:PARAM ERR if
n
out of range
5:ACCESS ERR if insufficient access
level
A1MUV (Analog input 1 Measure
Unit Value) Reads or sets the value of
measure units relative to the
totalizers.
Help command: A1MUV=?
List of
num:description
if accepted
1:CMD ERR if analog input 1 not
enabled
5:ACCESS ERR if insufficient access
level
Read command: A1SSV?
Start scale value of analog in.1 if
accepted
1:CMD ERR if analog input 1 not
enabled
5:ACCESS ERR if insufficient access
level
A1SSV (Analog input 1 Start Scale
Value) Reads or sets the value of the
start scale point for the analog input
1.
Set command: A1SSV=
n
0:OK if parameters accepted
1:CMD ERR if analog input 1 not
enabled
2:PARAM ERR if
n
out of range
5:ACCESS ERR if insufficient access
level