Programming the tank gauge – Franklin Fueling Systems TS-DIM User Manual
Page 24

24
Programming the Tank Gauge
NO. METERS: The total number of all Fueling Point Meters at the site. This is located under the SYSTEM menu. A value
above 0 will show the following menus:
RECONCILE: Enables reconciliation by programming schedule and time for gathering data. Located under the SETUP menu.
DIM Dispenser Interface: Program Meters, Fuel Points, and DIM address. This is located under the SETUP menu
REPORTS...RECONCILE: Program a schedule on a Shift basis, Daily schedule, Monthly basis, Shift History, or Daily
History — the RECONCILE menu is DIM-related and replaces the earlier Non-DIM Inventory Reconciliation menu
(reconcile is the last of the report choices)
TS-DIM Related Features
Sales and Delivery adjustment (in volume units) are available on a per-tank basis. These offsets allow adjustment to a
known discrepancy in reconciliation (e.g. when calibrating a meter, or when a product delivery doesn’t match the reported
delivery at the tank gauge).
Press MENU – DOWN – and M1 for SALES ADJ or M2 for DELIV ADJ.
SETUP
SYSTEM
Setup Menu
NO. METERS = 0
DIMM
METERS (100 meters supported)
METER N (shown typical)
DISPENSER INTERFACE
RECONCILE
SCHEDULE
TIME = 23:00:00
NONE
DAILY
SHIFT
Shift 1 = 7:00:00
HH:MM:SS 24 Hour Format Input time
Shift 2 = 15:00:00
HH:MM:SS 24 Hour Format Input time
HH:MM:SS 24 Hour Format
Input time (N/A for Shift)
Shift 3 = 23:00:00
HH:MM:SS 24 Hour Format Input time
(For 2 shifts, use same time for shift 2 & 3)
Input the total number of meters
at the site. (TS-DIM(s) sites)
Some prior-input values will be
present...correct as needed
FUEL PTS Fueling Points
FUEL PT = N
Fuel Point # from WinTester data
GRADE NO. = N
TANK A = N
Grade from WinTester data
FUEL PTS N Fueling Point N (shown typical)
DIM UNIT DIM Unit Number
Correct TS-DIM number
- FUEL PT = 1
DIM FL PT DIM Fueling Point
Correct Fuel Point # as req’d
- FUEL PT = N
Tank No. (Largest % of a blend)
TANK B = 0
Tank No. (Smallest % of a blend)
BLEND = 100
Blending Ratio % from Tank A
Input the correct Tank Number for Tank A & Tank B
Figure 19: Tank Gauge DIM Menu