Franklin Fueling Systems TS-DIM User Manual
Page 20

20
Accessing the Internal Diagnostics
The database section of the diagnostics will show the transaction totals for each fueling position.
1. At the DIAG-> prompt, enter D for the diagnostic section.
2. Next, at the Select Section: prompt, enter A for the database section.
3. At the DBASE-> prompt, enter D for the display pump block option.
4. Finally, at the Select: prompt, enter 0 for the total volume option.
5. The screen should look like that below.
Definitions
Fueling Point - anywhere a vehicle can stop and dispense fuel. Most dispensers have two fueling points (front and back).
Meter # (Product) - each type of product that can be dispensed from a fueling point (position) will be assigned a meter
number Hn (n = 1 through 8).
Grade # - the diagnostic program will show eight possible grades for each Fueling Point and assigns a Grade # to a Meter
(product) when you dispense each product at each fueling point (position).
Tank # - this is the Tank # in the FFS Tank Sentinel that the product will come from when dispensed from this Meter
(product). If this meter is a blended product, then supply both tank numbers and the blend-percentage from the
primary tank.
Blend % - is the percentage of the blend coming from the primary tank (the tank which supplies the greatest amount of
fuel to the blend) Primary non-blends = 100%.