Rack-mount Requirements
CAUTION
For rack-mounted installations, the following criteria must be observed (in addition to
the Environmental Requirements listed on page 25)
Mounting & Support
ALWAYS use the special rack-mount kits (available separately) to secure the VN-MATRIX. Full
details on using the kit are included with the kit. It will be necessary to remove the four feet prior to
rack mounting.
DO NOT stand other units directly on top of the VN-MATRIX when it is rack-mounted as this will place
excessive strain on the mounting brackets.
Ventilation
ALWAYS ensure that the rack enclosure is adequately ventilated. Sufficient airflow must be achieved
(by convection or forced-air cooling) to satisfy the ventilation requirements of all items of equipment
installed within the rack.
No additional ventilation gap is required above or below the VN-MATRIX and adjacent surfaces or
equipment.
Mains Supply
ALWAYS ensure that the mains power supply is of the correct voltage and frequency for all
equipment within the rack, and that it has a good ground/earth connection.
Where a power strip (mains distribution batten) is used (of either a hard-wired or plug and socket
type), always ensure that the current rating of both the power strip and the supply is sufficient for all
equipment within the rack.