RS-232 Serial I/O (COM1 and COM2)

Function: COM1 – used for low level setup or system recovery.

COM2 – used for cross-network serial communications or serial
remote control of the VN-MATRIX controller.

Connector Type: 9-pin D-type (male)

Pin-out Details:

Pin Function

Pin Function

1 DCD

6 DSR

2

RX (data in)

7

RTS

3

TX (data out)

8

CTS

4 DTR

9 RING

5 Ground


Mating Connector: 9-pin D-type (female)

with metal cover

Recommended Cable: 6-core plus overall screen (low capacitance),

0.22mm

2

min. per core.

Max. Cable Length: 2.95 metres (9.5 feet).

Comms Standard: RS-232.

COM1 Default Setting: Baud:

115200

Bits:

8

Parity:

None

Stop Bits:

1

Flow Control: None