Environmental Requirements
CAUTION
The criteria on this page must be observed for all installations of the VN-MATRIX,
whether free-standing or rack-mounted.
Orientation
The VN-MATRIX is designed to be used free-standing on a stable, horizontal surface. It can, however,
be used in any orientation subject to the necessary ventilation requirements.
Temperature
DO NOT install or operate the VN-MATRIX in an area where the ambient temperature exceeds 35°C
(95°F) or falls below 5°C (35°F).
Remember that, as with all electronic equipment, the VN-MATRIX and its associated PSU also
produces heat which may affect the ambient temperature.
After the VN-MATRIX has been in use for a period of time the external casing may become slightly
warm to the touch. Ensure that any adjacent surfaces will not be affected by the heat.
Ventilation
DO NOT obstruct the ventilation grilles during use. The VN-MATRIX has an integral forced-air cooling
system. A fan draws air in through the grille in the front panel and expels ‘warmed’ air through the
grilles in the back panel. The fan speed is controlled automatically by an internal temperature sensor.
The fan may, therefore, appear to run faster as the unit warms up or if the ambient temperature is
increased.
A self-resetting thermal cut-out will shutdown the VN-MATRIX if the temperature exceeds design
limits.
Humidity & Water
DO NOT install or operate the VN-MATRIX in an area in which the ambient relative humidity exceeds
85% or in an area that is prone to condensation.
DO NOT install or operate the VN-MATRIX near water or in a location which may be prone to water
seepage — the VN-MATRIX is not waterproof.