Serial interface – quick reference, Com2 port settings, Login procedure – Extron Electronics VN-MATRIX User Guide User Manual
Page 105: Command options
VN-MATRIX User Guide
Section 7: Technical Data
I458GB issue 6
Page 105
Serial Interface – Quick Reference
COM2 Port Settings
Baud
rate:
115200
Data
bits:
8
Parity:
None
Stop
bits:
1
Flow
control:
None
Login Procedure
From the Login: prompt, type config followed by the
When prompted for a password type config followed by the
The following menu will then appear.
Network Port 1 Network Port 2
============== ==============
1. Boot method: static [dhcp] 11. Boot method: static [dhcp]
2. address: 192.168.0.18 12. address: 192.168.1.18
3. netmask: 255.255.255.0 13. netmask: 255.255.255.0
4. gateway: 192.168.0.1
5. broadcast: 192.168.0.255 15. broadcast: 192.168.1.255
6. mtu: 1500 16. mtu: 1500
7. controller ip: 192.168.0.18
8. controller port: 5432 18. webserver port: 80
9. Exit
Type the menu option number required followed by the
Where required, type the new value followed by the
To exit the menu and return to the main command prompt type 9
Command Options
The following commands are also supported from the main command prompt:
Exit
to logout from the session
Reboot
to force the VN-MATRIX device to restart
Ping
to test network communications with another device (see page 127).