Front Panel Features


NETWORK II
STATUS

NETWORK I

POWER

ELECTROSONIC

Indicators


The following indicators are visible on the front of the VN-MATRIX:

Name

Color

Function

POWER Green

Fully Lit – when the unit is receiving power from the 12V supply input.

Flashing – an over temperature condition has occurred or there was a
power overload/underload condition. Cycle the power off/on to reset.

NETWORK I

Orange

Indicates the status of network port I:

Fully Lit or Flashing Intermittently – control or source data is being
transmitted or received by the port.

Unlit – no data or no network connection detected.

NETWORK II

Orange Indicates

the

status of network port II:

Fully Lit or Flashing Intermittently – control or source data is being
transmitted or received by the port.

Unlit – no data or no network connection detected.

STATUS

Green

Indicates the source status of the VN-MATRIX:

Condition

Encoder (source)

Decoder (display)

Unlit

No source input detected

No source being received

Flashing

Source being streamed

Source being received

Fully Lit

Source present but not
being streamed (e.g. unit
currently disabled or in
standby mode)

n/a


NOTE: During the VN-MATRIX boot up period (typically 20-30 seconds) the NETWORK and STATUS
indicators may light up or flash intermittently while the unit initializes.

Reset Button


VN-MATRIX is fitted with a concealed reset button. This can be used to reboot the operating system,
for example during firmware upgrade procedures.

To activate this button, insert the blade of a very small screwdriver (or similar tool) or straightened
paper clip into the hole on the front panel, on the left of the indicators.