Chapter 7 - Troubleshooting

ASUS GigaX2124

Table 9: Problems & suggested actions

Problem

Suggested Action

Network Access

PCs cannot display web

configuration pages.

1. The switch is powered up and the connecting port is

enabled. The factory default IP for the switch is 192.168.1.1.
2. Verify your network setup in your PC for this information.

If your PC does not have a valid route to access the switch,

change the switch IP to an appropriate IP that your PC can

access.
3. Ping “switch IP” from the PC, if it still fails, repeat step 2.
4. If ping is successful but the web configuration still fails,

connecting PC through the console port by a RS232 or USB,

check if any filter rule or static MAC address is set to block

the WEB traffics.

Web configuration interface

You forgot/lost your WEB

Configuration Interface

user ID or password.

1. If you have not changed the password from the default, try

using “admin” as the user ID and bypassing password.
2. Login to console mode through RS232 or USB, use com-

mand “w” in Boot ROM mode to reset password.

Some pages do not

display completely

1. Verify that you are using Internet Explorer v5.5 or later.

Netscape is not supported. Support for Javascript® must be

enabled in your browser. Support for Java® may also be re-

quired.
2. Ping the switch IP address to see if the link is stable. If

some ping packets fail, check your network setup to make

sure a valid setting.

Changes to Configuration

are not being retained.

Be sure to click <Save> in the Save Configuration page to

save any changes.

Console interface

Cannot show the texts

on the terminal emulator.

1. The factory default baud rate is 9600, no flow control, 8 bit

data, no parity check and stop bit is one.
2. Change your terminal emulator setup to this number. If you

are using USB to connect the switch, install the USB driver

first.
3. Check if the cable is good.