beautypg.com

B&B Electronics ZXT9-MB2A-KIT - Manual User Manual

Page 55

background image

Document Number: ZXTxRM-5110m

  

Page 
55
 

 

 

 

associated to a Coordinator. Maximum sleep period is 268 seconds
(0x68B0). Range is 0x1 to 0x68B0.

Serial Interfacing

: Change modem interfacing options.

Figure 5-34 Serial Interfacing (ZXT24-RM)

BD – Interface Data Rate

: Set/read the serial interface baud rate for

communication between modem serial port and host. Request non-
standard baud rates with values above 0x80 using a terminal window.
Read BD register to find actual baud rate achieved. This is a pull down
option. Selections are:

0 – 1200
1 – 2400
2 – 4800
3 – 9600
4 – 19200
5 – 38400
6 – 57600
7 – 115200

RD – Receive Packetization Timeout

: Set/read number of character

times of inter-character delay required before transmission begins. Set
to zero to transmit characters as they arrive instead of buffering them
into one RF packet. The range is 0x0 to 0xFF.

D7 – DIO7 Configuration

: Configure options for the DIO7 line of the

module. Options include: CTS flow control. This is a pull down option.
Selections are:

0 – Disable
1 – CTS Flow Control

D6 – DIO6 Configuration

: Configure options for the DIO6 line of the

module. Options include: RTS flow control. This is a pull down option.
Selections are:

0 – Disable