Document Number: ZXTxRM-5110m

  

Page 
14
 

 

 

 

3.2.2 Cable Gland Installation

 

1. The cable gland will accept cable diameters from 0.236 to 0.472 inches (5.99 to 11.99

mm).

2. Insert the Non-tapered end of the Body (D) through the conduit knock-out on the radio

modem enclosure.

3. Place the Gasket around the body on the outside of the enclosure.
4. Thread the Hex Nut onto the Body from the inside of the enclosure.
5. Place the Cable Nut onto the cable being careful to position the threaded side so that

it can be attached to the Cable Body.

6. Tighten the Cable Nut. This will cause the tapered end of the Cable Body to

compress, ensuring a water-tight seal.

3.3 Watertight Threaded Conduit Hub

3.3.1 Description


Another method to bring a cable into the enclosure is to use the water tight threaded
conduit hub. It is used to secure threaded half inch rigid service entrance conduit. It
consists of a Body, Nut, and Gasket.


Figure 3-5

½ Inch Threaded Conduit Hub

 

Figure 3-6

½ Inch Threaded Conduit Hub

 

3.3.2 Water Tight Threaded Conduit Installation

 

1. Insert the treaded end of the body into the conduit knock-out from the outside of the

enclosure. The rubber gasket should be on the outside of the enclosure.

2. Thread the Nut onto the conduit body from inside the enclosure.
3. 1/2 and 3/8 inch conduit fittings as well as 1/2 Inch, rigid, threaded conduit can be

attached to the threaded hub.