beautypg.com

Define still/start mode window – EVS IPDirector Version 5.6 - May 2009 Part 6 User's Manual User Manual

Page 72

background image

IPDirector Version 5.6 – User Manual – Part 6: Playout – Playlist Panel

EVS Broadcast Equipment – May 2009

Issue 5.6.D

63

If the playlist is in PAUSE or EDIT mode, the element on which a jump-on-time

is defined will be played with the speed defined for it but without its transition
parameters (A/V effect and duration).

If the playlist is loaded on a channel later than the time defined for the jump-on-
time, the playout of the element will not be triggered.

When a playlist is being played, the “remaining time until next transition” and
“remaining time until next break”, will be adapted taking into account the jump-

on-time condition.

Limitation for the Use of Jump on Time and/or Start on Time

Several triggers cannot be defined for the same playlist element, i.e. two jump-

on-time conditions, two start-on-time conditions or a start-on-time condition and
a jump-on-time condition.

Defining a new condition will remove or overwrite the first one.

Several triggers with the same time and date cannot be defined for the same
playlist.

Two triggers cannot be defined for the same playlist if their respective time and
date are too closed to each other, i.e. in the range [time-guardband,
time+guardband].

D

EFINE

S

TILL

/S

TART

M

ODE

W

INDOW

When right-clicking on a playlist element and selecting Define still/start mode

from the Playlist Element contextual menu, the Define Still/Start Mode window