a.

Set the

DPM TYPE

in the 3000 DPM Setup Menu

to

KSCOPE.

NOTE:

A delay has been introduced when changing DPM TYPE. This

delay allows a new DPM TYPE to be chosen without cycling through
intermediate DPM Types. Once the desired solution has been made, the
new DPM TYPE will be set 2 seconds later.

b. Turn the

EFF SEND DELAY

soft knob to select

2 fields.

It is

important that this delay be set correctly.

c.

Turn the

CONTROL DELAY

knob to select

6 fields.

d. Set

CHANNEL ROUTING,

for

SWR IN

or

BOTH,

depending

upon your system configuration, as described previously
under “Configuring a DPM.”

e.

Reset the Control Processor in the Model 3000 Signal
Processor frame. This is done by opening the front door of
the Processor and pressing the

RESET

button located near

the top of the Control Processor module in cell 17 of Bay B.

Communication should now be established between the
Model 3000 and Kaleidoscope.

For a DPM-700

a.

Set the

DPM TYPE

, to

OTHER FIXED.

b. Turn the

EFF SEND DELAY

soft knob to select

2 fields

. It is

important that this delay be set correctly.

(The

CONTROLDELAY

softknob has no effect with the

DPM-700.)

c.

Set

PORT ASSIGN

to

NONE.

d. Set

CHANNEL ROUTING

, to

OFF

.