For kaleidoscope, For a dpm-700 – Tektronix Grass Valley 3000 User Manual
Page 78
2-42
Section 2 — Startup & Configuration
For Kaleidoscope
a.
Set the
DPM TYPE
in the 3000 DPM Setup Menu
to
KSCOPE.
NOTE:
A delay has been introduced when changing DPM TYPE. This
delay allows a new DPM TYPE to be chosen without cycling through
intermediate DPM Types. Once the desired solution has been made, the
new DPM TYPE will be set 2 seconds later.
b. Turn the
EFF SEND DELAY
soft knob to select
2 fields.
It is
important that this delay be set correctly.
c.
Turn the
CONTROL DELAY
knob to select
6 fields.
d. Set
CHANNEL ROUTING,
for
SWR IN
or
BOTH,
depending
upon your system configuration, as described previously
under “Configuring a DPM.”
e.
Reset the Control Processor in the Model 3000 Signal
Processor frame. This is done by opening the front door of
the Processor and pressing the
RESET
button located near
the top of the Control Processor module in cell 17 of Bay B.
Communication should now be established between the
Model 3000 and Kaleidoscope.
For a DPM-700
a.
Set the
DPM TYPE
, to
OTHER FIXED.
b. Turn the
EFF SEND DELAY
soft knob to select
2 fields
. It is
important that this delay be set correctly.
(The
CONTROLDELAY
softknob has no effect with the
DPM-700.)
c.
Set
PORT ASSIGN
to
NONE.
d. Set
CHANNEL ROUTING
, to
OFF
.