Setting transition rates – Tektronix Grass Valley 3000 User Manual
Page 158

4-20
Section 4— Switcher Operations
Setting Transition Rates
You can adjust the transition rate for an auto transition or Key mix
(DSK mix on the 4000-2B) using any rate from 1 to 999 frames:
1.
In the E-MEM Subpanel , select
TRAN
RATE
. The query:
SET WHICH RATE?
displays.
2.
Delegate to the Transition subpanel that you want to set an
auto transition rate for by pressing
M/E 1, ME/2, PGM/PST,
or
DSK
. You can change all at once by pressing
ENABL ALL
.
3.
The display queries:
RATE
= ?
4.
Use the E-MEM numeric keypad to enter the number of
television frames for the transition rate. Enter a rate from
0 through 999.
5.
Press
ENTER
to complete the rate entry. (If 3 numbers are used
the completion is automatic. If less than 3 numbers are
entered, complete the entry with the
ENTER
button.) The
transition rate shown in the rate display near the associated
transition controls changes to the new rate.