beautypg.com

Operating the model 3000 with kaleidoscope, To enable the model 3000, To enable kaleidoscope – Tektronix Grass Valley 3000 User Manual

Page 106

background image

2-70

Section 2 — Startup & Configuration

Operating the Model 3000 With Kaleidoscope

After the Model 3000 has been connected to a Kaleidoscope DPM
(Digital Picture Manipulator), as described in the Installation
section of the Model 3000 Installation & Service manual, and after
the Model 3000 has been properly configured, as described earlier
in this section, all that is required for the two devices to operate
together is to enable both of them.

With both ends of the 3000/Kaleidoscope interface enabled,
communication is established which provides E-MEM recall and
run control.

To Enable the Model 3000

1.

Turn on (high tally) the

DPM

button that was configured for

Kaleidoscope (usually

DPM 1

) on the E-MEM Enables

subpanel.

2.

Bring up the DPM Setup Menu on the Model 3000 as follows:

a.

Press

CONFG

on the main menu panel.

b. Select

EXTERN I/F>

in the Configuration Menu.

c.

Select

DPM I/F>

in the External Interface Menu.

3.

Set the

DPM TYPE

in the 3000 DPM Setup Menu

to

KSCOPE.

To Enable Kaleidoscope

1.

Press the Kaleidoscope Top Menu

RESRCES

button.

2.

Select

USER PREFS

in the Resources Menu.

3.

Select

EXTRN CNTRL

in the User Preferences Menu.

4.

Select

ENABLE 3/4000

in the External Control Menu.