beautypg.com

Tektronix Grass Valley 3000 User Manual

Page 47

background image

2-11

Setting System Parameters

4.

Set the

END HORIZONTAL BLANKING

soft knob as desired.

This adjusts the end of H blanking over a range of -16.0 clocks
to +16.0 clocks. The default value is 0.0 clocks.

Pressing the

H-BLANKING DEFAULT

button resets the

horizontal blanking start and end values to Grass Valley
default settings (0.0 clocks).

5.

Set the

SUPERBLACK OUTPUT LEVEL

soft knob as desired.

This adjusts the super black output level over a range of -20.0
IRE to +7.5 IRE for U.S.A. NTSC, or -20.0 IRE to 0.0 IRE for the
Japanese NTSC.

6.

Set the

FIELD DOM

to

FIELD 1

,

FIELD 2

, or

NONE

. Refer to

page 2-64

.

7.

Select the desired matte generator chroma limiting algorithm
with the

MATTE GEN LIM

button. The selections are as follows:

XMITABL

— Prevents the total signal (luminance and

chrominance) from exceeding the NTSC transmission
standard.

VALID RGB

— Limits colors to those which generate red,

green, and blue values within the 0 to 100% range.

BOTH

— Selects a valid RGB color limiter that also

prevents the encoded signal envelope from exceeding
NTSC transmission level. (This is the system default
mode.)

NONE

— Turns off all algorithm methods for matte

generator limiting.

8.

The

SET CLOCK>

selection opens the Set Clock Menu, which

allows you to set the date and time for the system.