beautypg.com

Operating the model 3000 with a dpm-700, To enable the model 3000 – Tektronix Grass Valley 3000 User Manual

Page 104

background image

2-68

Section 2 — Startup & Configuration

Operating the Model 3000 With a DPM-700

This feature allows you to return a high tally from a DPM-700
when configured with the Model 3000. To use the DPM Logical
Channel Tally feature, connect the DPM-700 as described in the
Installation and Service manual.

To Enable the Model 3000

1.

From the Map Inputs Menu:

a.

Select

LOG CHANNEL

with the

LOG/PHYS ASSIGN

button.

b. Select

DPM 1 LOG CHAN 1

with the

VIDEO INPUT

soft knob.

c.

Select

DPM 1 LOG CHAN 1

with the

KEY INPUT

soft knob.

d. Select

NONE

with the

CHROMA KEY INPUT

soft knob.

2.

From the DPM Setup Menu:

a.

Choose

DPM 1

with the

DEVICE SELECT

button.

b. Choose

OTHER FIXED

with the

DPM TYPE

button.

3.

From the DPM Map Aux Buses Menu:

a.

Select

DPM 1.

b. Select

2

with the

NUMBER OF CHANNELS

soft knob.

c.

Select

AUX 1

with the

CHANNEL 1

soft knob.