Midi implementation 55, Rewind (mcs), Record strobe – Roland VS-1680 User Manual
Page 55: Record exit, Mmc reset, Write, Masked write, Locate(mcp)
● REWIND (MCS)
Status
Data Bytes
Status
F0H
7FH,Dev,06H,05H
F7H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
05H
REWIND (MCS)
F7H
EOX (End of System Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
1680 goes into the rewind condition. The VS-1680 does not transmit the message.
● RECORD STROBE
Status
Data Bytes
Status
F0H
7FH,Dev,06H,06H
F7H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
06H
RECORD STROBE
F7H
EOX (End of System Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
1680 goes into the following condition.
1. The VS-1680 is in the playback condition.
Start Recording the tracks that status are the record standby mode.
2. The VS-1680 is in the stop condition.
Start Playing back, and Start Recording the track that status are the record
standby mode.
If the transport switch [REC] was pressed out of the recording condition, the VS-1680 trans-
mits as the device ID 7FH.
● RECORD EXIT
Status
Data Bytes
Status
F0H
7FH,Dev,06H,07H
F7H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
07H
RECORD EXIT
F7H
EOX (End of System Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
1680 exits from the record condition. If the transport switch [REC] was pressed while
recording, the VS-1680 transmits as the device ID 7FH.
● MMC RESET
Statu
Data Bytes
Status
F0H
7FH,Dev,06H,0DH
F7H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
0DH
MMC RESET
F7H
EOX (End of System Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
1680 resets all communication channels related with MMC. When powered on the VS-1680
transmits as the device ID 7FH.
● WRITE
Status
Data Bytes
Status
F0H
7FH,Dev,06H,40H,ccH,ddH,eeH,,,ffH,,,
F7H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
40H
WRITE
ccH
Information Bytes follows the command
ddH
The name of the writable Information Field
eeH
Information Field Format
:
:
ffH
Field names and data
:
:
F7H
EOX (End of System Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
1680 writes the data to the specified information field. The VS-1680 does not transmit the
message.
● MASKED WRITE
Status
Data Bytes
Status
F0H
7FH,Dev,06H,41H,04H,ddH,eeH,ffH,ggH
F7H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
41H
MASKED WRITE
04H
Number of Bytes follows the command
ddH
The name of the masked type writable Information Field
eeH
Byte number to write in the Bit Map
ffH
Bit location of the bit map byte to change
ggH
New data to write to the specified bit map byte
F7H
EOX (End of System Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
1680 writes the data to the specified bit map byte. The VS-1680 does not transmit the mes-
sage.
● LOCATE(MCP)
❍ Format 1 - LOCATE[I/F]
Status
Data Bytes
Status
F0H
7FH,Dev,06H,44H,02H,00H,nnH
F7H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive Message Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
44H
LOCATE(MCP)
02H
Number of Bytes
00H
“I/F” sub command
nnH
Information Field (08H, 09H, 0AH, 0BH, 0CH, 0DH, 0EH, 0FH)
F7H
EOX (End of System Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the VS-
1680 locates the selected time location stored to the specified information field. The VS-1680
does not transmit the message.
MIDI Implementation
55