If a message appears, Battery low, Check sum error – Roland SC-88 Pro User Manual
Page 150: Midi buff. full, Midi off line, No instrument, No drum set, No patch
■
If a message appears
If operation is incorrect or if the data cannot be processed correctly, an error mes-
sage will appear in the display.
Consult the following list and take the appropriate action.
Battery Low
Cause
: The memory backup battery inside this unit has run down.
Action
: Consult a nearby Roland Service Station.
Check Sum Error
Cause
: The check sum of the received exclusive message is incorrect.
Action
: Check the data which was transmitted to this unit, and transmit it once
again. Also make sure that the MIDI cable is not broken.
MIDI Buff. Full
Cause
: A large amount of MIDI data was received by this unit in a time too short for
correct processing to be done.
Action
: Check whether a large amount of MIDI data is not being transmitted in a
short time.
MIDI Off Line
Cause 1
: It is possible that the power has been turned off for the MIDI device connect-
ed to MIDI IN.
Action 1
: The problem is not with this unit. Check the power of the connected MIDI
device.
Cause 2
: It is possible that a MIDI cable has been pulled out or broken.
Action 2
: Check the MIDI cables.
No INSTRUMENT
-------------
Cause
: A sound (Instrument) which this unit does not have has been selected.
Action
: The previously selected sound name will be displayed, and that sound will
be heard. Carefully refer to the tables on p.154 to 162, and specify the cor-
rect bank number and program number.
No DRUM SET
Cause
: A Drum Set which this unit does not have has been selected.
Action
: The previously selected Drum Set name will be displayed, and that set will
sound.
No PATCH
Cause
: A Patch which this unit does not have has been selected.
Actcion
: The previously selected Patch name will be displayed, and that Patch will
sound.