Data capture

217

General data capture

Before you run the show run-config or debug commands, enable text
capturing on your Hyper terminal or Telnet application that you use to
access the WLAN Security Switch 2270.

Multiple times is better—copy and paste the following commands on the
WLAN Security Switch 2270 CLI, rather than typing them individually. The
screen begins scrolling with output as soon as you type the commands.

show run-config (from all WLAN Security Switch 2270s)

show tech support

show msglog

The wired sniffer must sniff the Gig port of the WLAN Security Switch 2270.
No capture filter is required; get everything.

Obtain the wireless capture from the channel that the handsets currently
use. Configure the wireless sniffer to capture from only one channel. To
determine which channel, first show the client summary. Look for the MAC
of the client showing status associated and note the name of the AP beside
it. To see the channel that the AP operates on, show the advanced 802.11b
summary.

Follow the steps in

Procedure 30 "Obtaining the wired and wireless

captures" (page 217)

, to capture data to send to Nortel for analysis.

Procedure 30

Obtaining the wired and wireless captures

Step

Action

1

Run the command:

debug airwave-director all enable

Let this command run for 5 to 7 minutes.

2

Run the command:

debug disable-all

3

Run the following debug commands from the WLAN Security Switch
2270 (that you are testing) in the CLI:

debug dot11 mobile enable

debug dot11 state enable

debug mobility directory enable

debug mobility handoff enable

debug pem state enable

debug pem events enable

show debug