beautypg.com

Timing information, Table 27 timing – Nortel Networks NN43001-504 User Manual

Page 199

background image

Timing information

199

Short

Error code

Description

Action

SVP

No SVP Response

The phone cannot
communicate with the WLAN
IP Telephony Manager 2245.

Configure the Ethernet
switch port and SVP to
100/full. Forward the DHCP
option 151 to the IP of the
SVP server. Verify the
settings on the AP. Verify
that there is no 2.4 Ghz
interference of any kind.

SVP

No SVP IP

No static IP entered into
the phone for the WLAN IP
Telephony Manager 2245.

Check for a valid IP in the
phone. Check the license
management configuration.
Compare a working phone
code to the nonworking
phone code.

SW

No SW Found

No phone code is found on
the TFTP server.

Point the TFTP software to
the correct directory that
contains valid code.

System

System Locked

The WLAN IP Telephony
Manager 2245 is locked.

Dial in and verify that system
is locked. Soft reset the
SpectraLink infrastructure
through the menu system.

TFTP

TFTP Error(s)

A failure occurred during the
TFTP software update.

Check the TFTP software
(SolarWinds is not
compatible). Check
the TFTP configuration.
Forward option 66 in the
DHCP scope, to the IP
address of the TFTP server.

Timing information

The WLAN IP Telephony Manager 2245 sends payload packets to the
handset every 30 ms in a 5 ms window. The handsets are likely to
experience issues if the jitter between the WLAN IP Telephony Manager
2245 and the AP is greater than 5 ms. Ideally, jitter in this part of the
network is 1 ms or less.

Table 27
Timing

WLAN IP Telephony Manager 2245
to the AP

Handset to the
WLAN IP Telephony Manager 2245

Delay

100 ms

Delay

100 ms

Jitter

1 ms

Jitter

30 ms

Packet loss

2%

Packet loss

2%

Nortel Communication Server 1000

WLAN IP Telephony Installation and Commissioning

NN43001-504

01.02

Standard

Release 5.0

15 June 2007

Copyright © 2004-2007, Nortel Networks

.