Paradyne 3163 User Manual
Page 79
Configuration Options
C-3
3163-A2-GB20-10
March 1999
Table C-1
(2 of 2)
Network Interface Configuration Options
NET LLB: Enab
Next Enab Disab Prev
Network Initiated Line Loopback (LLB). Allows initiation and termination of the LLB to be controlled by the receipt of
LLB-Actuate and LLB-Release commands from the network (or remote DSU/CSU).
Enab – Causes the DSU/CSU to enter an LLB (if the DSU/CSU can perform an LLB in its current state) and to cause an
LLB-Release command to terminate the LLB.
Disab – Causes the DSU/CSU to ignore LLB-Actuate and LLB-Release commands (the DSU/CSU is not in compliance
with ANSI T1.403 and AT&T TR 62411).
NOTE: When this configuration option is enabled, the DSU/CSU recognizes the in-band LLB-Actuate and LLB-Release
codes specified by AT&T as well as the bit-oriented FDL messages specified by ANSI (for ESF only).
NET PLB: Enab
Next Enab Disab Prev
Network Initiated Payload Loopback (PLB). Allows initiation and termination of the PLB to be controlled by the receipt of
PLB-Actuate and PLB-Release commands from the network (or remote DSU/CSU).
Enab – Causes the DSU/CSU to enter a PLB (if the DSU/CSU can perform a PLB in its current state) and to cause a
PLB-Release command to terminate the PLB.
Disab – Causes the DSU/CSU to ignore PLB-Actuate and PLB-Release commands (the DSU/CSU is not in compliance
with ANSI T1.403 and AT&T TR 54016).
NOTE: When this configuration option is enabled, the DSU/CSU recognizes the in-band PLB-Actuate and PLB-Release
codes specified by AT&T as well as the bit-oriented FDL messages specified by ANSI.
NOTE: This configuration option is only available when the network interface framing is set to ESF.
Bit Stuff: 62411
Next 62411 Part68 Disab Prev
Bit Stuffing. Determines when bit stuffing is performed to meet the ones density requirements for data transmission on the
network. You must choose the maximum number of consecutive zeros the DSU/CSU can receive before it inserts a one.
62411 – Specifies that a one be inserted in the data stream after 15 consecutive zeros or when the density of ones falls
below 12.5% (complies with AT&T TR 62411).
Part68 – Specifies that a one be inserted in the data stream after 80 consecutive zeros (complies with FCC Part 68).
Disab – Disables bit stuffing so that ones density is not enforced.
NOTE: To comply with Canadian DOC CS-03 regulations, equipment installed in Canada must be configured to select
62411.
NOTE: To comply with USA Part 68 regulations, equipment installed in the USA must be configured to select Part 68.
NOTE: This configuration option is only available if the network interface line coding format is set to AMI.
Circuit Ident:
Next Edit Clear Prev
Network Circuit Identifier. Specifies the transmission vendor’s circuit identifier for the purpose of facilitating
troubleshooting. The network circuit identifier is an ASCII text string that may be up to 255 characters in length.
Edit – Allows you to edit and/or display the network circuit identifier using the generic text string entry screen.
Clear – Allows you to clear the network circuit identifier. The network circuit identifier is set to a null string.