Monitoring and Testing

4-17

3163-A2-GB20-10

March 1999

Aborting Test Patterns

Use the Abort command to stop all test patterns or any

selected test pattern active on the DSU/CSU.

"

Procedure

To abort test patterns:

1. From the top-level menu screen, select Test.

2. From the Test screen, select Ptrns.

F1

Test:
Rlpbk Lpbk

Ptrns

F2

F3

3. From the Patterns screen, select Abort.

F1

Patterns:
Abort

Send

Mon

F2

F3

4. From the Patterns Abort screen, press the desired

Function key to abort either All active test
patterns, active Send test patterns, or the active
Monitor (Mon) test pattern.

F1

Patterns: Abort
All

Send

Mon

F2

F3

If you select All, the DSU/CSU terminates all
active test patterns and displays the message
Command Complete. Skip Step 5.

NOTE

If you mistakenly choose to abort a
test pattern that is not currently
running, a Command Complete
message still displays and the test
pattern currently active still runs. Use
the TStat branch to view the test
status to determine if the abort was
successful.

5. From the Abort screen, press the Function key that

corresponds to the network or port for which you
want to abort a test pattern. Use the scroll keys, if
necessary.

F1

Abort:

Send or Mon

NET

Prt1

F2

F3

The DSU/CSU terminates the selected test pattern
and displays the message Command Complete.

Lamp Test

Use the Lamp Test commands to start and stop a test of

the DSU/CSU front panel LCD and LEDs.

Starting a Lamp Test

"

Procedure

To start a Lamp test:

1. From the top-level menu screen, select Test.

2. From the Test screen, press the

key until the

Lamp selection appears on the screen.

3. From the Test screen, select Lamp.