Displaying/editing configuration options – Paradyne 3163 User Manual
Page 32

ACCULINK 3163 DSU/CSU
3-10
March 1999
3163-A2-GB20-10
The configuration options are divided into functional
contains a list of the configuration
options and defaults. These groups are:
•
Port
•
Network Interface
•
Channel
•
General
•
User Interface
•
Alarm
•
Management
The DSU/CSU arrives with two preset factory default
configuration settings. These settings are based on the
following:
•
Factory 1 – ESF framing format with B8ZS line
coding format for the network interface. The data
port is unassigned.
•
Factory 2 – D4 framing format with AMI line
coding format for the network interface. The data
port is unassigned.
If neither of the factory default settings support your
network’s configuration, you can customize the
configuration options to better suit your application.
Use the Configuration (Cnfig) branch of the front panel
menu tree to display or change DSU/CSU configuration
options (see Appendix C,
Displaying/Editing Configuration Options
"
Procedure
To display/edit configuration options:
1. From the top-level menu screen, select Cnfig.
F1
DSU ESF
Stat
Test
Cnfig
F2
F3
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
F1
Load from:
Activ
Cust1
F2
F3
3. Select Edit.
F1
Choose Funct:
Edit
Save
F2
F3