ACCULINK 3163 DSU/CSU

3-10

March 1999

3163-A2-GB20-10

The configuration options are divided into functional

groups.

Appendix C

contains a list of the configuration

options and defaults. These groups are:

Port

Network Interface

Channel

General

User Interface

Alarm

Management

The DSU/CSU arrives with two preset factory default

configuration settings. These settings are based on the
following:

Factory 1 – ESF framing format with B8ZS line
coding format for the network interface. The data
port is unassigned.

Factory 2 – D4 framing format with AMI line
coding format for the network interface. The data
port is unassigned.

If neither of the factory default settings support your

network’s configuration, you can customize the
configuration options to better suit your application.

Use the Configuration (Cnfig) branch of the front panel

menu tree to display or change DSU/CSU configuration
options (see Appendix C,

Configuration Options

).

Displaying/Editing Configuration Options

"

Procedure

To display/edit configuration options:

1. From the top-level menu screen, select Cnfig.

F1

DSU ESF
Stat

Test

Cnfig

F2

F3

2. Select the configuration option set to be copied

into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.

F1

Load from:
Activ

Cust1

F2

F3

3. Select Edit.

F1

Choose Funct:
Edit

Save

F2

F3