beautypg.com

Technical specifications, Appendix b, Overview – Paradyne 3163 User Manual

Page 75

background image

B-1

3163-A2-GB20-10

March 1999

Technical Specifications

Overview

B-1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Overview

The technical specifications for the DSU/CSUs are

listed in Table B-1.

Table B-1

(1 of 2)

Models 3163 DSU/CSU Technical Specifications

Specifications

Criteria

POWER REQUIREMENTS
Typical:

AC Power Module

Optional:

+24 Vdc
– 48 Vdc
– 48 Vdc Redundant

Refer to the labeling on the ac power module for input requirements

+20 Vdc to +32 Vdc, 0.50A
–38 Vdc to – 60 Vdc, 0.25A
–38 Vdc to – 60 Vdc, 0.25A

POWER CONSUMPTION AND
DISSIPATION

16.0 watts, 55.0 Btu per hour at 115 volts (ac power); 12.0 watts, 41 Btu per hour
at +24 and – 48 Vdc (dc power)

NETWORK T1 INTERFACE

Physical Interface (USA)
Physical Interface (Canada)
Framing Format
Coding Format
Line Build-Out (LBO)
ANSI PRM
Bit Stuffing
Yellow Alarm Generation

RJ48C
CA81A using adapter cable
D4, ESF
AMI, B8ZS
0.0 dB, –7.5 dB, –15 dB, –22.5 dB
Selectable
FCC Part 68, AT&T TR 62411
Selectable

LOOPBACKS
Standard
Additional

AT&T TR 54016, AT&T TR 62411, ANSI T1.403.1989
RLB (Repeater Loopback), V.54 Loop 2 and Loop 3, ANSI T1.403 Annex B
Fractional T1 Loopback

PORT INTERFACE
Standards
Rates

EIA-530-A, V.35, RS-449, X.21
Nx64 – 64K-1.536 Mb
Nx56 – 56K-1.344 Mb

B