Self-test health, Self-test, Health – Paradyne 3163 User Manual

Page 54: Section in chapter 4, maintenance )

background image

ACCULINK 3163 DSU/CSU

4-2

March 1999

3163-A2-GB20-10

Self-Test Health

Use the Self-Test Health command to display the

results of the power-up self-test. Possible messages are
listed in Table 4-1. See Chapter 2,

Installation,

for more

information about power-up self-test.

"

Procedure

To display power-up self-test results:

1. From the top-level menu screen, select Stat.

F1

DSU ESF
Stat

Test

Cnfig

F2

F3

2. From the Status screen, select STest.

F1

Status:
DevHS STest

Perf

F2

F3

3. View the results of the last power-up self-test. If

no problems were found during power-up, the
following message appears.

F1

STest Health:
Passed

F2

F3

Table 4-1

Self-Test Health Messages

Message

Description

Passed

No problems were found during power-up.

CPU fail

The central processing unit failed internal testing.

Device fail

One or more of the unit’s integrated circuit chips failed to pass internal device level testing.

B8ZS/LOS fail

The unit failed to encode data properly or to detect Loss Of Signal.

Alarm fail

The unit failed to transmit AIS or to detect an Yellow alarm.

Memory fail

The unit failed program checksum verification.

LCD fail

The front panel liquid crystal display (LCD) failed.

NET T1 fail

The unit failed to internally loop data on the network T1 circuit.

DSU fail

The unit failed to internally loop data on the DSU.

DSU Port 1 fail

Port’s integrated circuitry failed to pass device internal testing.

Modem fail

Unit failed to internally loop data through the modem circuit.

Failure

xxxxxxxx

An 8-digit hexadecimal failure code is provided for service personnel.