Operation

3-23

3163-A2-GB20-10

March 1999

The inactive interface displays the following message

when a Function key is pressed or a connection is made
on the inactive user interface and control cannot be
switched because the currently active interface is in use.
On the screen, either Ft. Panel (front panel), Com Port, or
Modem is displayed in the user interface (User I/F ) field.

F1

DSU ESF
User I/F active

F2

F3

The inactive interface displays the following message

after control has been released from the previously active
interface and another interface has not become active.

F1

DSU ESF
User I/F idle

F2

F3

Releasing the Active User Interface

To release the current active user interface, either allow

five minutes to elapse without pressing any key or use the
Release command.

"

Procedure

To use the Release command:

1. From the top-level menu screen, press the

key

until the Ctrl selection appears on the screen.

2. Select Ctrl.

3. From the Control screen, select Rel (Release).

F1

Control:
Call

Rel

LED

F2

F3

The active user interface is released. The message
Released appears. No user interface is active until
input is received from a user interface.

Enabling/Disabling the Front
Panel

You can enable or disable the display of information on

the front panel. This feature is useful for ensuring that
other users do not inadvertently change the device’s
configuration options while you are using an external
device (e.g., a PC or async terminal). The factory default
is Enable.

NOTE

If you disable the front panel, be
sure not to alter the configuration
options for using an external
device (e.g., a PC or async
terminal). If this happens, you
lose the ability to communicate
with the device. You will need to
contact your service
representative.

"

Procedure

To enable or disable the front panel:

1. From the top-level menu screen, select Cnfig.

2. Select the configuration option set to be copied

into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.

3. Select Edit.

4. From the Edit screen, press the

key until the

User selection appears on the screen.

5. Select User.

6. Press F1 (Next) until the FP Access configuration

option appears.

7. Press F2 to enable the front panel or F3 to disable

the front panel.

F1

FP Access:
Next

Enab

Disab

F3

F2