beautypg.com

Technical data, Ils signal analysis – Procom VOR/ILS Analyzer EVS200 User Manual

Page 65

background image

VOR/ILS Analyzer EVS200

0796.1800.02

E-8

56

Chapter 6: Technical Specification

Technical data

Receiver section

Frequency range

................................ 74.7 to 75.3 MHz

107 to 119 MHz
319 to 341 MHz

Accuracy

................................

2 ppm

Resolution

................................ 5 kHz

Input voltage

................................ 15 dBm max./ 50

(data safety up to 10 dBm is ensured)

VSWR

................................ <1.5

Sensitivity

................................ -96 dBm

18 dB (IF bandwidth 8 kHz)

IF bandwidth

................................ min.

±

15 kHz (-3 dB), max.

±

40 kHz (-60dB)

min.

±

4 kHz (-3 dB), max.

±

12 kHz (-60dB)

or optional:
min.

±

19 kHz (-6 dB), max.

±

38 kHz (-60dB)

min.

±

8 kHz (-6 dB), max.

±

20 kHz (-60dB)

Demodulation

................................ AM

RF-Input

................................ BNC

Absolute-level receiver

Display range

................................ -96 to +10 dBm

Accuracy

................................ <

±

2 dB

Difference-level receiver

Bargraph (quasi analog)......................

±

12 dB to reference level

Resolution

................................ 0.1 dB

Accuracy indication .............................

≤ ±

1 dB

ILS signal analysis

The given values are valid only for the 30 kHz- or 38 kHz- IF-filter

RF level

................................ -70 to -30 dBm

Frequency range

................................ 108 to 118 MHz
................................ 328 to 336 MHz

Modulation depth (10 to 80 %)

90 / 150 Hz

±

2% ................................ accuracy 0.5%

300 Hz to 4 kHz (identifier)..................

1.2% of reading

Phase angle 90/150 Hz

Measurement range ............................

±

60°

Measurement error..............................

0.2°

Resolution

................................ 0.1°

DDM measurement

Localizer mode

Measurement error at
15 to 25% modulation..........................

≤ ±

0.0004 DDM

±

0.1% of reading

10 to 30% modulation..........................

≤ ±

0.0004 DDM

±

0.2% of reading