beautypg.com

Vor-mode – Procom VOR/ILS Analyzer EVS200 User Manual

Page 53

background image

VOR/ILS Analyzer EVS200

0796.1800.02

E-8

44

Chapter 3: Operation

VOR-Mode

Command BE

command

funcion

BE

bearing angle query

The command BE reads the actual bearing angle (indicated in degree) in the VOR mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

BE
be

e.g.

299.97DEG

e.g.

299.97DEG

Command AM0

command

function

AM0

query of AM-modulation depth (30 Hz)

The command AM0 reads the actual AM-modulation depth (30 Hz) in the VOR mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AM0
am0

e.g.

30.1%

e.g.

30.1%

Command AM1

command

function

AM1

query of AM-modulation depth (9960 Hz)

The command AM1 reads the actual AM-modulation depth (9960 Hz) in the VOR mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AM1
am1

e.g.

30.1%

e.g.

30.1%