Vor-mode – Procom VOR/ILS Analyzer EVS200 User Manual
Page 53

VOR/ILS Analyzer EVS200
0796.1800.02
E-8
44
Chapter 3: Operation
VOR-Mode
Command BE
command
funcion
BE
bearing angle query
The command BE reads the actual bearing angle (indicated in degree) in the VOR mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
BE
be
e.g.
299.97DEG
e.g.
299.97DEG
Command AM0
command
function
AM0
query of AM-modulation depth (30 Hz)
The command AM0 reads the actual AM-modulation depth (30 Hz) in the VOR mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AM0
am0
e.g.
30.1%
e.g.
30.1%
Command AM1
command
function
AM1
query of AM-modulation depth (9960 Hz)
The command AM1 reads the actual AM-modulation depth (9960 Hz) in the VOR mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AM1
am1
e.g.
30.1%
e.g.
30.1%