Procom VOR/ILS Analyzer EVS200 User Manual
Page 60

VOR/ILS Analyzer EVS200
0796.1800.02
E-8
51
Chapter 3: Operation
Command AM7
Kommando
Funktion
AM6
query of AM-modulation depth ID
The command AM7 reads the actual AM-modulation depth (ID) in the BEACON mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AM7
am7
e.g.
10.2%
e.g.
10.2%
Command AF4
command
function
AF4
query of AF-frequency 3000 Hz
The command AF4 reads the actual AF frequency (F1) in the BEACON mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AF4
af4
e.g.
3000.0Hz
e.g.
3000.0Hz
Command AF5
command
function
AF5
query of AF-frequency 1300 Hz
The command AF5 reads the actual AF frequency (F2) in the BEACON mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AF5
af5
e.g.
1300.0Hz
e.g.
1300.0Hz