Chapter 3: Operation

Command FM0

command

function

FM0

FM-deviation query

The command FM0 reads the actual FM-deviation value in the VOR mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

FM0
fm0

e.g.

479.1Hz

e.g.

479.1Hz

Command FM1

command

function

FM1

query of FM-index value

The command FM1 reads the actual FM-index value in the VOR mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

FM1
fm1

e.g.

15.9

e.g.

15.9

Command D1

command

function

D1

switching over to Display1

The command D1 enables the switching over to the content of display1 in the VOR / ILS mode.

This is the prediction for reading out the data of the corresponding mode (VOR/ILS).

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

input:

D1
d1

READY
READY