Command EC1
command
function
EC1
selection of communication
EVS200 retransmits the received control string.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
EC1
ec1
READY
READY
Command test
command
function
TEST
< >
RS232 test section output
The command TEST initiates a RS232 test section. All ASCII characters 20h to FF will be supplied.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
EC1
ec1
READY
READY
Command LA
command
function
LA
query of receiving level
The command LA reads the actual receiving signal level in "
∆∆∆∆
Level"-mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
LA
la
e.g.
-48.1dBm
e.g.